Norge: norskNorge: norsk
International: english
International: englishInternational: english
Australia: english
Australia: englishAustralia: english
Austria: deutsch
Austria: deutschAustria: deutsch
Canada: english
Canada: englishCanada: english
Czechia: český
Czechia: českýCzechia: český
Denmark: dansk
Denmark: danskDenmark: dansk
Finland: suomi
Finland: suomiFinland: suomi
France: français
France: françaisFrance: français
Germany: deutsch
Germany: deutschGermany: deutsch
Hungary: magyar
Hungary: magyarHungary: magyar
Italy: italiano
Italy: italianoItaly: italiano
Netherlands: nederlands
Netherlands: nederlandsNetherlands: nederlands
Norge: norsk
Norge: norskNorge: norsk
Poland: polski
Poland: polskiPoland: polski
Romania: românesc
Romania: românescRomania: românesc
Slovakia: slovenčina
Slovakia: slovenčinaSlovakia: slovenčina
Spain: español
Spain: españolSpain: español
Sweden: svenska
Sweden: svenskaSweden: svenska
Switzerland: deutsch
Switzerland: deutschSwitzerland: deutschfrançais
UAE: english
UAE: englishUAE: english
United Kingdom: english
United Kingdom: englishUnited Kingdom: english
USA: english
USA: englishUSA: english

How to: Separation layer for sheet pile retaining walls

© www.maxfrank.com

Sheet piles are used as permanent or temporary support of excavations. Pecafil® permanent formwork acts as a sacrificial back shutter for the concrete liner wall, the sheet piles are spanned and do not need to be filled with concrete. As a result, concrete volume is significantly reduced, offering considerable cost savings – especially in basement construction using waterproof concrete (Type B).

Pecafil also functions as a separation layer to aid extraction of sheet piles by acting as a slip membrane and reducing contact area with the wall.

Available in a range of grades to suit different pour pressures and pile profiles, Pecafil can be supplied in sheets up to 6m x 2.4m to quickly face the wall and speed up construction.

How to:

  • Pecafil sheets can be prefabricated to required size.
  • Fasten the boards to the substrate using a stud gun or by welding.
  • Mount the reinforcement and formwork. In selecting the spacers, attention should be paid to a high load distribution (e.g. through bar spacers), so that the foil is not punctured.
  • Following concreting the sheet piles can be removed, depending on the construction.

Video-Instruction for Pecafil® Separation Layer